MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 45kw.
SLD converter rated current: 93A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
The motor efficiency is not changed in the previous optimal excitation control,
At the same time, the newly developed advanced optimal excitation control can obtain larger torque at startup FX3G-422-BD Manual FX3G-422-BD INSTALLATION MANUAL
FX3G-422-BD
No need to adjust the parameters (plus deceleration time or torque, etc.), in a short time to speed up to a certain speed,
Can be carried out to maximize the efficiency of energy-saving drive motor.
The automatic tuning function of the loop constant of the motor is not consistent with the constant of the motor, the motor of other manufacturers, and the length of wiring is too long,
Optimum operating characteristic drive motor FX3G-422-BD Manual FX3G-422-BD INSTALLATION MANUAL.
In the state of the sensor can not only drive the high efficiency and energy saving motor and PM motor (MM-EFS), but also can drive other companies induction motor and PM motor (permanent magnet synchronous motor).
Other manufacturers of induction motors, can also be automatically tuned to achieve the best excitation control, thus expanding the use of energy saving FX3G-422-BD Manual FX3G-422-BD INSTALLATION MANUAL. Power: 15kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity.
At the same time the installation options in the use of 75kW and above motor. (the IP55 series has a built-in DC reactor.)
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) MITSUBISHI inverter FR-D720S series.
Voltage level: single phase 200V.
Frequency converter capacity: 0.2KW.
VVVF frequency control, vector control frequency conversion, direct torque control is a kind of AC - DC - AC frequency conversion.
The common drawback is that the input power factor is low, the harmonic current is big, and the DC circuit needs large energy storage capacity,
Renewable energy and can not be fed back to the power grid, which can not be carried out in the four quadrant operation. To this end, the matrix type of AC - AC variable frequency arises at the historic moment.
Because the matrix type alternating current frequency saves the intermediate DC link, thereby, the electrolytic capacitor with large volume and high price can be omitted.
It can achieve a powwer factor of L, the input current is sinusoidal and can run in four quadrant, the power density of the system is large FX3G-422-BD Manual FX3G-422-BD INSTALLATION MANUAL.
Although the technology is not yet mature, but still attract a large number of scholars in-depth study FX3G-422-BD Manual FX3G-422-BD INSTALLATION MANUAL.
In fact, the quality is not the indirect control current, flux, but the torque is directly used as the control to achieve.