Master station module for CC-Link/LT.
I/O control can be used in the province of CC-LINK/LT.
Is to make PLC CC-LINK/LT as the main station of the FX system module.
The master station module and the remote I/O module can be connected by a special connector, and achieve the purpose of the distribution of the province FX1N-40MT-DSS Manual FX1N-40MT-DSS HARDWARE MANUAL.
Up to 64 remote I/O station modules can be connected
FX1N-40MT-DSS
Remote I/O module is assigned a common X, Y soft components,
By using the same procedure as the common input and output.
Even if the use of 2 points, 4 points of the remote I/O module, the number of soft components can be continuously assigned,
So it can be efficiently allocated I/O. Max input / output points: 16 points.
Power supply voltage: 24VDC FX1N-40MT-DSS Manual FX1N-40MT-DSS HARDWARE MANUAL.
Input points: 8 points.
Output points: 8 points.
Output type: Transistor (sink).
Power consumption: 6W.
Weight (kg):0.2.
Size (WxHxD) mm:35x90x87.
Taking into account space saving and processing speed.
Connector input and output type compact high performance universal machine.
Compact, scalable input / output.
Can connect analog quantity, communication, positioning, etc FX1N-40MT-DSS Manual FX1N-40MT-DSS HARDWARE MANUAL. .
Rich special extension equipment for FX2N.
By connecting the compact FX2rvc series with the input and output expansion module.
The input and output can be extended to 256 points.
Built in 8000 step RAM memory.
By installing the memory card box, the maximum can be extended to the 16000 step.
Overseas oriented products meet all kinds of international standards.
Use terminal module to replace connector connection or relay terminal row connection,
So as to save the wiring inside the cabinet. Cable length: 10 meters.
For FXCPU (FX0, FX0S, FX0N, FX1S, FX1N, FX2N, FX2NC,) and GOT connection.
For FXCPU expansion board FX2N-422-B, FX1N-422-BD and GOT connectionn FX1N-40MT-DSS Manual FX1N-40MT-DSS HARDWARE MANUAL. Function: terminal row input.
Input points: 16 points.
Connected programmable logic controller: FX1NC, FX2NC, FX3UC.
Weight: 0.15KG.
FX2NC expansion module can be directly connected to the FX1NCC, FX2NC, PLC FX3UC on the expansion of the input and output FX1N-40MT-DSS Manual FX1N-40MT-DSS HARDWARE MANUAL.
Do not need to connect the cable and so on, therefore can carry on the compact expansion.