Function: RS-232C communication.
Adapter for connecting the left extension function of the CPU module.
CPU module can be connected to the left side up to 6 units. Max input / output points: 14 points.
Power supply voltage: 24VDC.
Input points: 8 points.
Output points: 6 points.
Output type: relay.
Power consumption (W): 6 FX1N-24MT-ES/UL Manual FX1N-24MT-ES/UL HARDWARE MANUAL. 5.
Weight (kg):0.22
FX1N-24MT-ES/UL
Size (WxHxD) mm:60x90x49.
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor FX1N-24MT-ES/UL Manual FX1N-24MT-ES/UL HARDWARE MANUAL.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication.
All equipment is digital input and output point.
The total I/O points are not more than 30 points, and the input points are less than 16, the output points are less than 14 FX1N-24MT-ES/UL Manual FX1N-24MT-ES/UL HARDWARE MANUAL.
Its MT series of PLC can drive 2 way servo or stepper, commonly used in the control system for a simple manipulator. "MITSUBISHI inverter series: FR-A846.
Voltage level: three phase 400V.
Power: 0.75kw.
SLD converter rated current: 3.8A.
Structure and function: IP55 counterpart.
Type: CA.
Substrate coating: have.
Built in DC reactor.
Easy to operate, simple settings.
We have prepared a series of equipment and functions for you to work in any place to meet the life cycle of the product.
Allegedly, the motor power consumption accounted for about half of the total power generated by manufacturing industry consumption.
How to achieve energy efficiency in the plant without affecting the productivity.
Less energy consumption and more output FR-A800 series inverter will help you to have both fish and bear''s paw"
Parameters and frequency settings can be modified in the program.
Inverter control, for example, by the input signal to trigger the operation of the inverter, based on the operation of the inverter
The status of the signall output, as well as the monitor output and so on, can be customized according to the requirements FX1N-24MT-ES/UL Manual FX1N-24MT-ES/UL HARDWARE MANUAL.
The control of each machine can be done separately by the frequency converter, and the controol of the dispersion is also carried out FX1N-24MT-ES/UL Manual FX1N-24MT-ES/UL HARDWARE MANUAL.
Through combining with the real-time clock function can realize the automatic operation (in option FR-LU08). "