LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI FR-F740P-160K-CHT Applied Manual FR-F740P-160K-CHT Instruction manual
Product model: FR-F740P-160K-CHT
Name: INVERTER
Brand: MITSUBISHI
Sort: Applied Instruction manual
File language: English
Power: 185kw.
Purpose: to suppress the power harmonics.
Connected to the inverter input, can be used to improve the power factor, reduce the input side of the high harmonic current.
According to the motor power used to select AC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose FR-F740P-160K-CHT Applied Manual FR-F740P-160K-CHT Instruction manual FR-F740P-160K-CHT ) MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 5.5KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%) FR-F740P-160K-CHT Applied Manual FR-F740P-160K-CHT Instruction manual.
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load FR-F740P-160K-CHT Applied Manual FR-F740P-160K-CHT Instruction manual. Can be isolated to obtain DC24/48/100V, AC100/200V input signal.Total points: 24 points.
Input points: 14 points.
Output points: 10 points.
Voltage: AC220V.
Output type: relay.
Outline dimension: 90*75*90.
FX1N series is a very powerful micro PLC,
Can be extended to up to 128 I/O points,
And can increase the special function module or the expansion board.
Communication and data link function options make FX1N in the volume, communication and special function modules and other important applications is very perfect. Memory format: RAM.
Number of steps: up to 16000 steps can be used.
Battery support: required.
Method for writing and deleting: the device is installed on the PLC, and is written and deleted by the periphheral device FR-F740P-160K-CHT Applied Manual FR-F740P-160K-CHT Instruction manual. Applicable models: FX2NC-20GM.
The contents of the RAM memory in FX2N-10GM, FX3UC, FX2N-20GM and FX3U are built up.
In addition, it is also required to use the backkup relay and the data register and the time of the data register FR-F740P-160K-CHT Applied Manual FR-F740P-160K-CHT Instruction manual.
As FX3G, FX3GE, FX3GC with the option,
The use of soft components other than EEPROM.
Related products
MITSUBISHI
3 phase 400V converter
FR-F740P-220K-CHT
MITSUBISHI 3 phase 400V converter FR-F740P-220K-CHT
"MITSUBISHI inverter FR-F740P series. Vo
MITSUBISHI
3 phase 400V converter
FR-F740P-37K-CHT
MITSUBISHI 3 phase 400V converter FR-F740P-37K-CHT
"MITSUBISHI inverter FR-F740P series. Vo
MITSUBISHI
3 phase 400V converter
FR-F740P-22K-CHT
MITSUBISHI 3 phase 400V converter FR-F740P-22K-CHT
"MITSUBISHI inverter FR-F740P series. Vo
MITSUBISHI
3 phase 400V converter
FR-F740P-280K-CHT
MITSUBISHI 3 phase 400V converter FR-F740P-280K-CHT
"MITSUBISHI inverter FR-F740P series. Vo