Max input / output points: 10 points.
Power supply voltage: DC24V.
Input points: 6 points.
Output points: 4 points.
Output type: Transistor (source).
Power consumption (W): 19.
Weight (kg):0.3.
Size (WxHxD) mm:60x90x75.
Positioning and pulse output functions: a PLC cell can output 2 point 100KHz pulses at the same time FR-F720-22K Applied Manual FR-F720-22K Instruction manual.
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute or relative address expression and special pulse output control
FR-F720-22K
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain FR-F720-22K Applied Manual FR-F720-22K Instruction manual.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication FR-F720-22K Applied Manual FR-F720-22K Instruction manual. The analog output adapter (FX3U- - racy -BD)MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 1.5kw.
SLD converter rated current: 10.5A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Compatibility with existing models.
Transducer installation size and FR-F700 (P) series of the same, so you do not need to worry about the replacement operation.
(rectifier separation type will vary)
Also, but also through the use of options (FR-A8TAT), FR-F700 (P) series installed control loop terminal station.
Built in 2 PID arithmetic. In the inverter can be PID control of the motor state at the same time, used in the control of the external machine.
No external PID controller is used to control the external machine, so the system cost can be reduced. MITSUBISHI inverter series: FR-F820.
Voltage level: three phase 200V.
Power: 22kw.
SLD converter rated current: 125A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
PID target value can be set directly from the operator panel. Flexible change settings.
In the 1 inverter, through the PID control of parallel connection pump (up to 4 units) can adjust the amount of water and so on.
1 pumps driven by parallel connection of the pump machine, in addition to the pump for power frequency drive FR-F720-22K Applied Manual FR-F720-22K Instruction manual.
The number of power frequency driven pump, according to the automatic adjustment of water.
The liquid crystal panel options (FR-LU08) can be converted too a more intuitive display unit% units FR-F720-22K Applied Manual FR-F720-22K Instruction manual.
Through the use of wind, temperature and other familiar units can be simple to maintain and adjust the display.