MITSUBISHI FR-E740-016 to 300-NA Manual FR-E740-016 to 300-NA INSTRUCTION MANUAL
Product model: FR-E740-016 to 300-NA
Name: INVERTER
Brand: MITSUBISHI
Sort: INSTRUCTION MANUAL
File language: English
Power: 220kw.
Voltage: 400V.
Purpose: high frequency braking resistor.
The braking ability provided by the braking capacity is larger than that provided by the external braking resistor.
Can also be connected without built-in brake transistor inverter.
Three types of discharge resistors are available FR-E740-016 to 300-NA Manual FR-E740-016 to 300-NA INSTRUCTION MANUAL.
Please select according to the required braking torque FR-E740-016 to 300-NA MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 45kw.
SLD converter rated current: 233A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight) FR-E740-016 to 300-NA Manual FR-E740-016 to 300-NA INSTRUCTION MANUAL.
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, to reduce the volume of equipment).
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network FR-E740-016 to 300-NA Manual FR-E740-016 to 300-NA INSTRUCTION MANUAL.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps. Max input / output points: 16 points.
Power supply voltage: 24VDC.
Input points: 8 points.
Output points: 8 points.
Output type: Transistor (source).
Power consumption: 20W.
Weight (kg):0.6.
Size (WxHxD) mm:130x90x87.
Developed a range of special function modules to meet the needs of different - analog I/O, high speed counter.
Positioning control to achieve the 16 axis, the pulse train output or for the J and K type thermocouple or Pt sensor developed the temperature module.
A total of 8 special function modules can be configured for each FX2n main unit.
Note recording function, Component annotation can be recorded in the program register.
Online program editor, online change the program will not lose the working hours or stop production operation.
RUN/STOP switch, running on panel / stop switch easy to operate.
Remote maintenance, remote programming software can monitor, upload or uninstall programs and data via modem communications
Password protection, using a eight digit password to protect your prograam FR-E740-016 to 300-NA Manual FR-E740-016 to 300-NA INSTRUCTION MANUAL.
Clock function and hour meter function, all of the PLC FX2N has a real-time clock standard.
Continuous scanning function, to define the operation cycle for the application off the continuous scan time FR-E740-016 to 300-NA Manual FR-E740-016 to 300-NA INSTRUCTION MANUAL.
Input filter adjustment function, you can use the input filter to smooth the input signal (in the basic unit x000 to x017).