MITSUBISHI FR-E720-11K BASIC Manual FR-E720-11K Instruction manual
Product model: FR-E720-11K
Name: INVERTER
Brand: MITSUBISHI
Sort: BASIC Instruction manual
File language: English
Max input / output points: 20 points.
Power supply voltage: 24VDC.
Input points: 12 points.
Output points: 8 points.
Output type: relay.
Power consumption (W): 7.
Weight (kg):0.3.
Size (WxHxD) mm:75x90x49.
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types FR-E720-11K BASIC Manual FR-E720-11K Instruction manual.
This type of PLC is mainly used in all of the digital input, digital output control point of the device FR-E720-11K
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O FR-E720-11K BASIC Manual FR-E720-11K Instruction manual.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication.
All equipment is digital input and output point.
The total I/O points are not more than 30 points, and the input points are less than 16, the output points are less than 14.
Its MT series of PLC can drive 2 way servo or stepper, commonly used in the control system for a simple manipulator FR-E720-11K BASIC Manual FR-E720-11K Instruction manual. The analog input adapter (FX3U- - racy -BD)Can be isolated from the output of the programmable controller, the a/b/c contact relay, SSR, Tr output.MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 7.5KW.
When the inverter is running, the starting current and starting torque of the motor are how?
With the operation of the inverter, with the acceleration of the motor to improve the frequency and voltage,
The starting current is limited to 150% below the rated current (according to the different types of aircraft, 125%~200%).
Starting with power frequency power supply, the starting current is 6~7 times of the rated current, therefore, the impact on the mechanical and electrical FR-E720-11K BASIC Manual FR-E720-11K Instruction manual.
The inverter drive can be smoothly start (start time longer).
The starting current is 1.2~1.5 times of the rated current, and the starting torque is 70%~120%% rated torque;
For the inverter with the torque automatic enhancement function, the starting torque is more than 100%, which can start with full load FR-E720-11K BASIC Manual FR-E720-11K Instruction manual.
Related products
MITSUBISHI
3 phase 200V converter
FR-E720-2.2K
MITSUBISHI 3 phase 200V converter FR-E720-2.2K
MITSUBISHI inverter FR-E720 series. Volt
MITSUBISHI
3 phase 200V converter
FR-E720-0.75K
MITSUBISHI 3 phase 200V converter FR-E720-0.75K
MITSUBISHI inverter FR-E720 series. Volt
MITSUBISHI
3 phase 400V converter
FR-E740-0.75K-CHT
MITSUBISHI 3 phase 400V converter FR-E740-0.75K-CHT
MITSUBISHI inverter FR-E740 series. Volt
MITSUBISHI
3 phase 200V converter
FR-A720-11K
MITSUBISHI 3 phase 200V converter FR-A720-11K
MITSUBISHI inverter FR-A720 series. Volt