MITSUBISHI FR-CVL-H15K Manual FR-CVL-H15K Instruction manual
Product model: FR-CVL-H15K
Name: POWER REGENERATION COMMON CONVERTER
Brand: MITSUBISHI
Sort: Instruction manual
File language: English
The output signal from the transducer can optionally host standard in the 3 class, as a relay contact output.MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 2.2kw.
SLD converter rated current: 5.2A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have FR-CVL-H15K Manual FR-CVL-H15K Instruction manual.
2 times the power consumption of the wind turbine and pump and the speed of the 3 power consumption is proportional to the speed of the rotating speed FR-CVL-H15K
Through the speed control of the frequency converter to adjust the air flow, can reduce the power consumption.
Give full play to the performance of the motor.
The excitation current is always adjusted to the best state, which can improve the efficiency of the motor FR-CVL-H15K Manual FR-CVL-H15K Instruction manual.
Load torque is smaller, can further improve energy efficiency.
For example, when a general motor is used, the optimal excitation control mode in the 4% motor load torque is about 30% more than that of the V/F control. Function extension board for RS-485 communication.
No DC24V consumption, do not take up input and output. Cable flat cable;
Connector with 20 pin installed at both ends of the fuse FR-CVL-H15K Manual FR-CVL-H15K Instruction manual.
Length 3M. MITSUBISHI inverter FR-D740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 3.7KW.
The internal and back of the inverter structure considering the cooling effect, the relationship between the upper and lower ventilation is also important,
Therefore, in order for the type of unit, hanging on the wall to the vertical position, the installation of vertical as possible.
Transducer can be used to drive a single phase motor? Can single phase power supply be used?
Basically can not be used. For a single phase motor with governor switch, the auxiliary winding will be burnt when the speed is below the operating point;
For the capacitor start or capacitor operation mode, the capacitor explosion will be induced FR-CVL-H15K Manual FR-CVL-H15K Instruction manual.
The inverter power suupply is usually 3, but the capacity for small, single-phase power is also useful functioning aircraft FR-CVL-H15K Manual FR-CVL-H15K Instruction manual. Adapter RS-232 communication (FX3U- - racy -BD).
Related products
MITSUBISHI
Brake resistance
FR-BR-H15K
MITSUBISHI Brake resistance FR-BR-H15K
"Power: 15kw. Voltage: 400V. Brake resis
MITSUBISHI
Common DC bus converter
FR-CV-55K
MITSUBISHI Common DC bus converter FR-CV-55K
Power: 55kw. Voltage: 200V. There are 10
MITSUBISHI
Common DC bus converter
FR-CV-30K
MITSUBISHI Common DC bus converter FR-CV-30K
Power: 30kw. Voltage: 200V. There are 10
MITSUBISHI
Surge voltage suppression filter
FR-BMF-H15K
MITSUBISHI Surge voltage suppression filter FR-BMF-H15K
Power: 15kw. Voltage: 400V. The surge vo