MITSUBISHI FR-A840-09620-2-60 PLC FUNCTION Manual FR-A840-09620-2-60 Programming Manual
Product model: FR-A840-09620-2-60
Name: INVERTER
Brand: MITSUBISHI
Sort: PLC FUNCTION Programming Manual
File language: English
MITSUBISHI inverter FR-D720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 1.5KW.
Vector control variable frequency speed control is the practice of the asynchronous motor in the three-phase coordinate system of the stator current Ia, Ib, Ic, through the three-phase to two-phase transformation,
The alternating current of Ia1Ib1 is equivalent to a two phase stationary coordinate system, and then is rotated by the rotor field oriented,
Equivalent to the DC current Im1, It1 (Im1 equivalent to DC motor excitation current in synchronous rotating coordinate system;
It1 equal to the armature current proportional to the torque, and then imitate the DC motor control method, to obtain the DC motor control,
The control of asynchronous motor is realized through the corresponding inverse coordinate transformation FR-A840-09620-2-60 PLC FUNCTION Manual FR-A840-09620-2-60 Programming Manual FR-A840-09620-2-60 PLC FUNCTION Manual FR-A840-09620-2-60 Programming Manual FR-A840-09620-2-60 Power: 5.5kw.
Purpose: to suppress the power harmonics.
Improve the power factor, reduce the input side of the high harmonic current.
Make sure that this option is installed in the FR-A820-03800 (75K) and FR-A840-02160 (75K) and above capacity and above capacity FR-A840-09620-2-60 PLC FUNCTION Manual FR-A840-09620-2-60 Programming Manual.
At the same time the installation options in the use of 75kW and above motor. (the IP55 series has a built-in DC reactor.)
According to the motor power used to select the DC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose.) Input output cable for A6TBXY36 type connector / terminal row conversion module.
Length 1.5M. Power: 15kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table.
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessary to take protective measures and cooling FR-A840-09620-2-60 PLC FUNCTION Manual FR-A840-09620-2-60 Programming Manual.
MYS type resistor can be used. But please pay attention to the allowable brake use rate.
Do not remove the terminal P/+ and P1 between thhe short circuit chip, in addition to connecting the DC reactor FR-A840-09620-2-60 PLC FUNCTION Manual FR-A840-09620-2-60 Programming Manual.
The installation of thermal relay, to avoid overheating and burn the braking resistor.