MITSUBISHI FR-A741-5.5K to 55K Applied Manual FR-A741-5.5K to 55K INSTRUCTION MANUAL
Product model: FR-A741-5.5K to 55K
Name: INVERTER
Brand: MITSUBISHI
Sort: Applied INSTRUCTION MANUAL
File language: English
Convert connector to screw relay terminal.
According to the location of the connection equipment distribution module. Max input / output points: 20 points.
Power supply voltage: DC24V.
Input points: 12 points.
Output points: 8 points.
Output type: relay.
Power consumption (W): 20.
Weight (kg):0.4.
Size (WxHxD) mm:75x90x75 FR-A741-5.5K to 55K Applied Manual FR-A741-5.5K to 55K INSTRUCTION MANUAL.
Positioning and pulse output functions: a PLC cell can output 2 point 100KHz pulses at the same time FR-A741-5.5K to 55K
PLC is equipped with 7 special positioning instructions,
Including zero return, absolute or relative address expression and special pulse output control.
Host has 10 points (6I/4O), 14 points (8I/6O), 20 points (12I/8O), 30 points (16I/14O) of 4 types.
This type of PLC is mainly used in all of the digital input, digital output control point of the device FR-A741-5.5K to 55K Applied Manual FR-A741-5.5K to 55K INSTRUCTION MANUAL.
Can be directly connected to the 220V city power, built-in 8K step EEPROM memory, no battery, easy to maintain.
The series transistor output (MT) of the PLC, can be output 2 100KHz pulse, direct drive servo or stepper motor.
The series PLC can not be brought with the expansion module, but can be installed by the BD board to extend a small amount of I/O FR-A741-5.5K to 55K Applied Manual FR-A741-5.5K to 55K INSTRUCTION MANUAL.
The series 1N through the installation of BD series PLC board, can achieve RS232, RS485, RS422 communication. Used to reduce radio noise.MITSUBISHI inverter series: FR-F840.
Voltage level: three phase 400V.
Power: 11kw.
SLD converter rated current: 25.0A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
2 times the power consumption of the wind turbine and pump and the speed of the 3 power consumption is proportional to the speed of the rotating speed.
Through the speed control of the frequency converter to adjust the air flow, can reduce the power consumption.
Give full play to the performance of the motor.
TThe excitation current is always adjusted to the best state, which can improve the efficiency of the motor FR-A741-5.5K to 55K Applied Manual FR-A741-5.5K to 55K INSTRUCTION MANUAL.
Load torque is smaller, can further improve energy efficiency.
For example, when a general motor is used, the optimal excitation control mode in the 4% motor load torque is about 30% more than that of the V/F control FR-A741-5.5K to 55K Applied Manual FR-A741-5.5K to 55K INSTRUCTION MANUAL.