Product model: FR-A740-185K-CHT
Name: INVERTER
Brand: MITSUBISHI
Sort: Applied INSTRUCTION MANUAL
File language: English
Use: power cord for basic unit.
Length: 1.0m.
Auxiliary parts for FX3GC and FX3UC. MITSUBISHI inverter FR-F720 series.
Voltage level: three phase 200V.
Frequency converter capacity: 37KW.
When the ring is opened, the frequency converter is provided with a load of the motor when the motor is operated with a load at a given frequency,
The range of the motor speed in the rated slip ratio (1%~5%) changes FR-A740-185K-CHT Applied Manual FR-A740-185K-CHT INSTRUCTION MANUAL FR-A740-185K-CHT
For the requirements of relatively high precision, even if the load changes are also required to operate at a given speed of the occasion,
Inverter with PG feedback function can be used (selection).
If the given acceleration time is too short, the output frequency of the inverter is far more than the change of the speed (electric angular frequency),
Converter will be due to flow over the current trip, the operation stopped, which is called stall FR-A740-185K-CHT Applied Manual FR-A740-185K-CHT INSTRUCTION MANUAL. Power: 110kw.
Purpose: to suppress the power harmonics.
Connected to the inverter input, can be used to improve the power factor, reduce the input side of the high harmonic current.
According to the motor power used to select AC reactor.
(when the inverter capacity is greater than the motor capacity, is still based on the motor capacity to choose FR-A740-185K-CHT Applied Manual FR-A740-185K-CHT INSTRUCTION MANUAL. ) Power: 22kw.
Purpose: high frequency braking resistor.
The use rate of the built-in regenerative brake of the transducer can be promoted.
When using the FR-ABR type brake resistor, the short circuit piece between the terminal PR-PX is removed. Does not remove the short circuit chip will lead to overheating of the brake resistor.
The utilization rate of the regenerative braking should be less than the allowable brake use rate in the above table.
With the operating frequency of the brake resistor to reach 300 degrees C or higher, it is necessarry to take protective measures and cooling FR-A740-185K-CHT Applied Manual FR-A740-185K-CHT INSTRUCTION MANUAL.
MYS type resistor can be used. But please pay attention to the allowable brake use rate.
Do not remove the terminal P/+ and P1 between thhe short circuit chip, in addition to connecting the DC reactor FR-A740-185K-CHT Applied Manual FR-A740-185K-CHT INSTRUCTION MANUAL.
The installation of thermal relay, to avoid overheating and burn the braking resistor.
Related products
MITSUBISHI
3 phase 400V converter
FR-A740-37K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-37K-CHT
MITSUBISHI inverter FR-A740 series. Volt
MITSUBISHI
3 phase 400V converter
FR-A740-5.5K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-5.5K-CHT
MITSUBISHI inverter FR-A740 series. Volt
MITSUBISHI
3 phase 400V converter
FR-A740-280K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-280K-CHT
MITSUBISHI inverter FR-A740 series. Volt
MITSUBISHI
3 phase 400V converter
FR-A740-0.4K-CHT
MITSUBISHI 3 phase 400V converter FR-A740-0.4K-CHT
MITSUBISHI inverter FR-A740 series. Volt