LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI FR-A5AR Manual FR-A5AR INSTRUCTION MANUAL
Product model: FR-A5AR
Name: TRANSISTORIZED INVERTER
Brand: MITSUBISHI
Sort: INSTRUCTION MANUAL
File language: English
MITSUBISHI inverter series: FR-F842.
Voltage level: three phase 400V.
Power: 560kw.
SLD converter rated current: 1212A.
Structure and function: the rectification part is off type.
Type: CA.
Substrate coating: have.
Energy saving by high efficiency motor.
Reduce standby power consumption.
DC24V external power supply, the input MC signal can be stopped after the motor for the OFF, in the motor drive for the ON FR-A5AR Manual FR-A5AR INSTRUCTION MANUAL FR-A5AR
Standby power management can be carried out by means of frequency converter to realize the power consumption reduction of standby time.
According to the temperature of the inverter cooling fan, the operation of the inverter can be controlled.
According to the operating conditions of the inverter cooling fan output the corresponding signal,
Therefore, the inverter and other built-in fan and inverter cooling fan synchronous operation FR-A5AR Manual FR-A5AR INSTRUCTION MANUAL.
Can reduce the power consumption in the stop. "MITSUBISHI inverter FR-F740 series.
Voltage level: three phase 400V.
Frequency converter capacity: 3.7KW.
The use of frequency converter motor is in order to speed, and reduce the starting current.
In order to produce a variable voltage and frequency, the device is the first power of the AC power conversion to DC (DC), the process is called rectification FR-A5AR Manual FR-A5AR INSTRUCTION MANUAL.
The direct current (DC) is transformed into alternating current (AC) and its scientific term is "inverter" (inverter).
General inverter is the DC power supply inverter for a certain fixed frequency and a certain voltage of the inverter.
For the inverter as the frequency adjustable, adjustable voltage inverter, we called the inverter. "MITSUBISHI inverter series: FR-A820.
Voltage level: three phase 200V.
Power: 45kw.
SLD converter rated current: 233A.
Structure and function: Standard model.
Type: CA.
Substrate coating: have.
Parameters can be selected by 4 different rated current and different overload rating (SLD (ultra light load) rated, LD (light load) rating, ND (general load) rating, HD (weight).
Type load) for selection.
You can choose the most suitable frequency converter for use; and by selecting a transducer with a SLD or LD rated level,
Be able to reduce the size of the device (compared with the FR-A700 series, too reduce the volume of equipment) FR-A5AR Manual FR-A5AR INSTRUCTION MANUAL.
For applications that require high torque at low speeds, the HD rating is the most suitable.
The controller is used to control and monitor the frequency converter through the network FR-A5AR Manual FR-A5AR INSTRUCTION MANUAL.
Standard corresponding RS-485 communication (MITSUBISHI converter protocol, Modbus-RTU protocol) data transmission speed up to 115200bps.
Related products
MITSUBISHI
3 phase 200V converter
FR-E720-1.5K
MITSUBISHI 3 phase 200V converter FR-E720-1.5K
MITSUBISHI inverter FR-E720 series. Volt
MITSUBISHI
3 phase 400V converter
FR-F740-5.5K-CHT
MITSUBISHI 3 phase 400V converter FR-F740-5.5K-CHT
"MITSUBISHI inverter FR-F740 series. Vol
MITSUBISHI
PROFIBUS-DP communication
FR-A8NP
MITSUBISHI PROFIBUS-DP communication FR-A8NP
The operation, monitoring, parameter mod