Output type: transistor output, drain type.
Output points: 4 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.1A.
External connection: 2 wire.
Screw terminal table type.
Minimum size of industry.
The connection object at a glance with terminal cover plate CL1X4-D1B2 Manual CL1X4-D1B2 User's Manual.
Input module for public end of positive pole and negative pole
CL1X4-D1B2
Terminal table structure capable of connecting with 2 wire type sensor and load in the same condition.
Can be installed along the 6 direction. Support Ver.2 CC-LINK. "Input type: DC input, positive public end / negative public end.
Input points: 2 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/4mA CL1X4-D1B2 Manual CL1X4-D1B2 User's Manual.
Output form: transistor output, leakage type.
Output points: 2 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0.1A.
External connection: 2 line /2 line type.
Screw terminal table type.
Minimum size of industry.
The connection object at a glance with terminal cover plate.
Input module for public end of positive pole and negative pole CL1X4-D1B2 Manual CL1X4-D1B2 User's Manual.
Terminal table structure capable of connecting with 2 wire type sensor and load in the same condition.
Can be installed along the 6 direction. Input type: DC input, positive common end.
Input points: 4 points.
Input response time: 0.5ms below /1.5ms.
Rated input voltage / current: DC24V/4mA.
External connection: 3 wire.
Sensor connection type.
Minimum size of industry.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. Input type: DC input, positive public end / negative public end.
Input points: 2 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/4mA.
Output form: relay output.
Output points: 2 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC30V/AC250V/2A.
Externall connection: 2 line /2 line type CL1X4-D1B2 Manual CL1X4-D1B2 User's Manual.
Screw terminal table type.
Minimum size of industry.
The connection object at a glance with terminal cover plate.
Input module for public end of positive pole and negativve pole CL1X4-D1B2 Manual CL1X4-D1B2 User's Manual.
Terminal table structure capable of connecting with 2 wire type sensor and load in the same condition.
Can be installed along the 6 direction.