MITSUBISHI AY50-UL Manual AY50-UL User's Manual
Product model: AY50-UL
Name: PLC
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Output points: 32 points.
Voltage: DC24V.
OFF leakage current: 0.1mA.
Output type: bidirectional thyristor output (type sink).
Response time: 2ms.
32 points / a common end.
50 point terminal station.
With the surge absorber.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh AY50-UL Manual AY50-UL User's Manual.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read AY50-UL
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program AY50-UL Manual AY50-UL User's Manual.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive AY50-UL Manual AY50-UL User's Manual.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear. Using A1SJ71LP21 and A1SJ71BR11MELSECNET/10 modules,
Can be any ANSCPU module to the network system.
Two options can be provided; the optical cable token ring network and the coaxial cable token bus network.
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on.
This phenomenon is called the I/O delay time effect.
Switch volume control is designed to,
According to the current input combination of the switch quanntity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order AY50-UL Manual AY50-UL User's Manual.
So, sometimes also known as the order control.
And seqquential control is divided into manual, semi-automatic or automatic AY50-UL Manual AY50-UL User's Manual.
And the control principle is decentralized, centralized and hybrid control three.
Related products
MITSUBISHI
Transistor output module
AY51
MITSUBISHI Transistor output module AY51
Output points: 32 points. Voltage: DC12/
MITSUBISHI
Transistor output module
AY51-S1
MITSUBISHI Transistor output module AY51-S1
Output points: 32 points. Voltage: DC12/
MITSUBISHI
Bidirectional thyristor output module
AY51C
MITSUBISHI Bidirectional thyristor output module AY51C
Output points: 32 points. Voltage: DC12/
MITSUBISHI
Transistor output module
AY50
MITSUBISHI Transistor output module AY50
Output points: 16 points. Voltage: DC12/