MITSUBISHI AY15CEU Manual AY15CEU User's Manual
Product model: AY15CEU
Name: I/O MODULE
Brand: MITSUBISHI
Sort: User's Manual
File language: English
3C-2V/5C-2V coaxial cable between double loop PC (control station / common station) / remote I/O network (remote master station).
Q mode.
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program AY15CEU Manual AY15CEU User's Manual AY15CEU
Input status and input information input from the input interface,
CPU will be stored in the working data memory or in the input image register.
And then combine the data and the program with CPU.
The result is stored in the output image register or the working data memory,
And then output to the output interface, control the external drive AY15CEU Manual AY15CEU User's Manual.
Semiconductor circuit with memory function.
System program memory and user memory.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear AY15CEU Manual AY15CEU User's Manual.
User memory: user program storage area and work data storage area.
Composed of random access memory (RAM). User use.
Power cut off. Commonly used efficient lithium battery as a backup power supply, life is generally 3~5 years. Input points: 16 points.
Voltage: DC48V.
Current: 4mA.
Response time: 10ms.
8 points / a common end.
Positive / negative.
20 point terminal station.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read.
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC AY15CEU Manual AY15CEU User's Manual.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program tto do the compiler to compile the process of interpretation AY15CEU Manual AY15CEU User's Manual.
Read only memory. Manufacturers use, content can not be changed, power does not disappear.
Related products
MITSUBISHI
Relay output module
AY15CEU
MITSUBISHI Relay output module AY15CEU
Output points: 24 points. Voltage: DC24V
MITSUBISHI
Relay output module
AY15EU
MITSUBISHI Relay output module AY15EU
Output points: 24 points. Voltage: DC24V
MITSUBISHI
Relay output module
AY11AEU
MITSUBISHI Relay output module AY11AEU
Output points: 16 points. Voltage: DC24V
MITSUBISHI
Relay output module
AY13E
MITSUBISHI Relay output module AY13E
Output points: 32 points. Voltage: DC24V