MITSUBISHI AX20-UL Manual AX20-UL User's Manual
Product model: AX20-UL
Name: PLC
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Output type: transistor output, source.
Output points: 16 points.
OFF leakage current: 0.1mA.
Output protection function.
Rated load voltage / current: DC24V/DC24V/0.1A.
External connection: 3 wire.
Sensor connector type (E-CON type).
Using industry standard E-CON type.
Simple wiring through sensor connector AX20-UL Manual AX20-UL User's Manual.
When installing the module can choose to use the DIN guide rail or screw mounting AX20-UL
3 wire sensor input. DC input points: 16 points.
Input voltage and current: 3/7mA, DC12/24V.
Response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 12 points.
Output voltage and current: DC24V/AC240V, 2A/1 point, 5A/1 common end.
Response time: 12ms.
8 point /1 a public end, 3 point /1 a common end, independent contact AX20-UL Manual AX20-UL User's Manual.
Output form: relay output.
36 point terminal station.
Number of stations: 4 stops.
Compact remote I/O unit.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system AX20-UL Manual AX20-UL User's Manual.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the fieldd signal, which is simple and easy to operate, but it is not easy to guarantee the timeliness AX20-UL Manual AX20-UL User's Manual.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of proogrammer AX20-UL Manual AX20-UL User's Manual. Self service (IN, OUT): SI optical cable.
Other aspects (IN, OUT): SI optical cable.
Data link anomaly Bureau bypass.
Inter agency extension.
Related products
MITSUBISHI
Input module
AX21EU
MITSUBISHI Input module AX21EU
Input points: 32 points. Voltage: AC200
MITSUBISHI
Input module
AX20
MITSUBISHI Input module AX20
Input points: 16 points. Voltage: AC200
MITSUBISHI
Input module
AX21C
MITSUBISHI Input module AX21C
Input points: 32 points. Input voltage:
MITSUBISHI
Input module
AX21
MITSUBISHI Input module AX21
Input points: 32 points. Voltage: AC200