LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI AJ71QC24-R2 Hardware Manual AJ71QC24-R2 User's Manual
Product model: AJ71QC24-R2
Name: Communications Module
Brand: MITSUBISHI
Sort: Hardware User's Manual
File language: English
For A6TBXY36/A6TBXY54/A6TBX70E (common cathode; drain type) long 3m.G1-62.5/125 fiber optic cable.
Double loop.
PC inter network (management station / station) / remote I/O network (remote control station).
How to choose MITSUBISHI PLC.
MITSUBISHI PLC options include the choice of MITSUBISHI PLC models, capacity, I/O module, power, etc AJ71QC24-R2 Hardware Manual AJ71QC24-R2 User's Manual. .
MITSUBISHI PLC distribution I/O points and design MITSUBISHI PLC peripheral hardware circuit
Draw the I/O point of the PLC and the input / output device connection diagram or the corresponding table,
This part also can be carried out in second steps AJ71QC24-R2
Design PLC peripheral hardware circuit.
Draw the electrical wiring diagram of the other parts of the system,
Including the main circuit and the control circuit does not enter the PLC, etc AJ71QC24-R2 Hardware Manual AJ71QC24-R2 User's Manual. .
The electrical schematic diagram of the system composed of I/O PLC connection diagram and PLC peripheral electrical circuit diagram.
So far the system''s hardware electrical circuit has been determined. Adapter for mounting rails. CPU unit.Bus connection.
Program 1 channel connection.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures AJ71QC24-R2 Hardware Manual AJ71QC24-R2 User's Manual.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
MITSUBISHI PLC protection and chain procedures.
Protection and chain is an indispensable part of the program, must be carefully considered.
It can avoid the control logic confusion caused by illegal operations. Input and output points: 512 points.
Input / output data points: 512 points.
Program capacity: 14K.
Basic command processing speed (LD command) s:1.0.
Coaxial data communication line function.
It is possible for AnNCPU to use ACPU as a sequential program.
The order of the ACPU program is to the following command;
In addition to a special broadcast on that can be used with AnNCPU.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4.
Integral type: the PLC componentts are installed together or a few pieces of printed circuit board,
And together with the power supply installed in the casing to form a single overall called the host or the basic unit, small, ultra small PLC using this structure AJ71QC24-R2 Hardware Manual AJ71QC24-R2 User's Manual AJ71QC24-R2 Hardware Manual AJ71QC24-R2 User's Manual.
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance.
Related products
MITSUBISHI
Computer communication module
A1SJ71UC24-R2
MITSUBISHI Computer communication module A1SJ71UC24-R2
Interface: RS232C. Transmission distance
MITSUBISHI
Ethernet module
AJ71QE71N-B5T
MITSUBISHI Ethernet module AJ71QE71N-B5T
Ethernet network module 10BASE-T/10BASE5
MITSUBISHI
Ethernet module
AJ71QE71N-B5
MITSUBISHI Ethernet module AJ71QE71N-B5
10BASE5. For Q mode. Control layer /MELS
MITSUBISHI
Coaxial cable module
AJ71QBR11
MITSUBISHI Coaxial cable module AJ71QBR11
3C-2V/5C-2V coaxial cale. Single us. P