LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI AJ71E71N-T Manual AJ71E71N-T User's Manual
Product model: AJ71E71N-T
Name: Ethernet Interface Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Input points: 16 points.
Input voltage and current: 3/7mA DC12/24V.
Input response time: 10ms.
16 point /1 a public side.
Positive and negative sharing.
Output points: 16 points.
Output voltage: DC24V/AC240V, 2A/1 point, 4A/ common end.
Output response time: 12ms.
Output type: relay output.
8 point /1 a public end, 4 points / a public end AJ71E71N-T Manual AJ71E71N-T User's Manual.
50 point terminal station AJ71E71N-T
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points AJ71E71N-T Manual AJ71E71N-T User's Manual.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process AJ71E71N-T Manual AJ71E71N-T User's Manual.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points. Output type: relay output.
Output points: 8 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC24V/AC240V/2A.
External connectionn: 2 wire AJ71E71N-T Manual AJ71E71N-T User's Manual.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool AJ71E71N-T Manual AJ71E71N-T User's Manual.
Related products
MITSUBISHI
Ethernet module
AJ71QE71N-T
MITSUBISHI Ethernet module AJ71QE71N-T
10BASE-T. For Q mode. Control layer /MEL
MITSUBISHI
Network module
AJ71E71N-B5T
MITSUBISHI Network module AJ71E71N-B5T
Ethernet network module 10BASE-T/10BASE5
MITSUBISHI
Network module
AJ71E71N-B2
MITSUBISHI Network module AJ71E71N-B2
10BASE2. When communicating in the PLC n
MITSUBISHI
Network module
A1SJ71E71N-T
MITSUBISHI Network module A1SJ71E71N-T
10BASE-T MITSUBISHI PLC is the main prod