Product model: AD75P2
Name: Positioning Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Cable length: 30 meters.
For QCPU and GOT (need A9GT-QCNB) connection.
For the connection between GOT and GOT. Input points: 16 points.
Input voltage and current: 3/7mA DC12/24V.
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 12 points.
Output voltage: DC12V/24V AD75P2 Manual AD75P2 User's Manual.
OFF leakage current: 0.1mA.
Output response time: 2ms.
Output type: transistor output AD75P2
8 point /1 a public end, 4 point /1 a public end.
36 point terminal station.
With the surge absorber.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points AD75P2 Manual AD75P2 User's Manual.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process AD75P2 Manual AD75P2 User's Manual.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signall and fan fault signal AD75P2 Manual AD75P2 User's Manual.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drivee system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points AD75P2 Manual AD75P2 User's Manual.
Related products
MITSUBISHI
Positioning module
AD71-S2
MITSUBISHI Positioning module AD71-S2
2 axes. 2 axis linear interpolation. Con
MITSUBISHI
Positioning module
RD75P2
MITSUBISHI Positioning module RD75P2
"Transistor output. Axis of control: 2.
MITSUBISHI
Open collector output
QD75P2
MITSUBISHI Open collector output QD75P2
2 axes, open collector output type. 2 ax