MITSUBISHI AD59 Manual AD59 User's Manual
Product model: AD59
Name: Memory card interface module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
2 slots.
Can be installed in the power supply unit for A series units installed QnA/.
Cannot extend.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage AD59 Manual AD59 User's Manual.
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load AD59
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action AD59 Manual AD59 User's Manual.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point AD59 Manual AD59 User's Manual.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30%.
The following describes the centralized control system I/O points of the estimate. ME-NET interface unit.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC initialization procedure. After MITSUBBISHI PLC on power, the general need to do some of the initial operation,
In order to start making necessary preparations, to avoid the wrong operation of the system AD59 Manual AD59 User's Manual.
The main contents of the initialization program arre: to some data area, counter and so on,
Data needed to restore some of the data area,
Set or reset some relays,
For some initial state display, etc AD59 Manual AD59 User's Manual. .
Related products
MITSUBISHI
Positioning module
AD70
MITSUBISHI Positioning module AD70
1 axes. Control unit: pulse. Determine t
MITSUBISHI
Intelligent communication module
AD51H-S3
MITSUBISHI Intelligent communication module AD51H-S3
BASIC program running. RS-232 2 channel,
MITSUBISHI
High speed counting module
AD62C
MITSUBISHI High speed counting module AD62C
1 channels. 50/10kpps. Count input signa