Output points: 24 points.
Voltage: DC24V/AC240V, 2A/1 point, 5A/1 public end.
OFF leakage current: 0.1mA.
Output type: relay output.
Response time: 12ms.
8 point /1 a public side.
36 point terminal station.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor A956GOT-SBD SW4D5C-GOTR-PACKE compatible Connection System Manual Manual A956GOT-SBD User's Manual
A956GOT-SBD
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc A956GOT-SBD SW4D5C-GOTR-PACKE compatible Connection System Manual Manual A956GOT-SBD User's Manual. .
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process A956GOT-SBD SW4D5C-GOTR-PACKE compatible Connection System Manual Manual A956GOT-SBD User's Manual.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points. Output type: transistor drain.
Output points: 64 points.
Load voltage: DC12/24.
Load current: 0.1A.
Connection mode: terminal row.
Common public end points: 32.
Structured text language is a programming language that describes a program with a structured description of the text.
It is a programming language similar to a high level language. In large and medium
Structured text is often used to describe the relationship between the various variables in the control system based on the PLC system.
Mainly used for other programming languages more difficult to achieve the user program.
The structured text programming language uses the computer description method to describe the various kinds of relations between the various variables in the system,
Complete the required function or operation.
Most PLC manufacturers use structured text programming language similar to BASIC language, PASCAL language or C language and other advanced languages,
But in order to be convenient, the expression methods of the statement and the types of statements are simpliffied A956GOT-SBD SW4D5C-GOTR-PACKE compatible Connection System Manual Manual A956GOT-SBD User's Manual.
Structured text programming language features: the use of high-level language programming, you can complete the complex control operations,
Needd to have a certain level of computer knowledge and programming skills,
Higher requirements for engineering designers A956GOT-SBD SW4D5C-GOTR-PACKE compatible Connection System Manual Manual A956GOT-SBD User's Manual. Poor visibility and operability.