LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI A956GOT-SBD-M3-B Hardware Manual A956GOT-SBD-M3-B User's Manual
Product model: A956GOT-SBD-M3-B
Name: touch screen
Brand: MITSUBISHI
Sort: Hardware User's Manual
File language: English
Output points: 16 points.
Voltage: DC24V/AC240V, 2A/1 point, 16A/ all points.
OFF leakage current: 0.1mA.
Output type: relay output.
Response time: 12ms.
All points of independence.
38 point terminal station.
With the surge absorber.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor A956GOT-SBD-M3-B Hardware Manual A956GOT-SBD-M3-B User's Manual A956GOT-SBD-M3-B
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc A956GOT-SBD-M3-B Hardware Manual A956GOT-SBD-M3-B User's Manual. .
In general, a reversible DC drive system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process A956GOT-SBD-M3-B Hardware Manual A956GOT-SBD-M3-B User's Manual.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points. MITSUBISHI PLC online debugging.
On-line debugging is the process that will through the simulation debugging to further carry on the on-line unification to adjust.
On-line debugging process should be step by step,
From MITSUBISHI PLC only connected to the input device, and then connect the output device, and then connect to the actual load and so on and so on stepp by step A956GOT-SBD-M3-B Hardware Manual A956GOT-SBD-M3-B User's Manual A956GOT-SBD-M3-B Hardware Manual A956GOT-SBD-M3-B User's Manual.
If you do not meet the requirements, the hardware and procedures for adjustment.
Usually only need to modify the part of the program can be.
Related products
MITSUBISHI
6 inch man machine interface
A956GOT-TBD
MITSUBISHI 6 inch man machine interface A956GOT-TBD
Series Name: A956GOT. Size: 6 inches. Re
MITSUBISHI
6 inch man machine interface
A956GOT-LBD-M3
MITSUBISHI 6 inch man machine interface A956GOT-LBD-M3
Series Name: A956GOT. Size: 6 inches. Re
MITSUBISHI
6 inch man machine interface
A956GOT-SBD
MITSUBISHI 6 inch man machine interface A956GOT-SBD
Series Name: A956GOT. Size: 6 inches. Re
MITSUBISHI
6 inch man machine interface
A956GOT-SBD-M3
MITSUBISHI 6 inch man machine interface A956GOT-SBD-M3
Series Name: A956GOT. Size: 6 inches. Re