LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI A64RD3C Manual A64RD3C User's Manual
Product model: A64RD3C
Name: Pt100 input module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Input and output points: 480 points.
Input / output data points: 480 points.
Program capacity: 8k.
Basic command processing speed (LD command) s:1.25.
RAM memory capacity: 32K, power supply (DC24V).
Modular: PLC is the basic components of a separate module.
Medium and large PLC used this way. Easy maintenance A64RD3C Manual A64RD3C User's Manual.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage A64RD3C
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load A64RD3C Manual A64RD3C User's Manual.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
User program storage capacity: it is a measure of how much the user application can store the number of indicators.
Usually in words or K words as units. 16 bit binary number is a word,
Every 1024 words are 1K words A64RD3C Manual A64RD3C User's Manual. PLC to store instructions and data in words.
General logical operation instructions each account for 1 words. Timer / counter,
Shift instruction accounted for 2 words. Data operation instructions for 2~4. Cable length: 3 meters.
Connection between FX1N-232-BD and FXCPU for GOT expansion board. Input points: 32 points.
Input voltage and current: 7mA DC24V.
Input response time: 10ms.
16 point /1 a public side.
Positive pole sharing.
Output points: 24 points.
Output voltage: DC24V/AC240V, 2A/1 point, 5A/1 common end.
Output response time: 12ms.
Output type: relay output.
8 point /1 a public side.
34 point terminal station.
PLC is introduced by the relay control technology after the development of micro processing technology,
Can be easily and reliably used for switching control.
As the analog quantity can be converted into digital quantity, the number of digital quantity is just a number of switching value,
Therefore, after the conversion of analog, PLC can also be reliable for processing control.
Because the continuous production process often has the analog quantity, the analog quantity control is sometimes called process control.
Analog quantity is not electricity, and PLC can only handle digital quantity, quantity of electricity.
All to realize the conversion between them to have the sensor, the analog quantity into a number of power.
If this power is not standard, but also through the transmitter,
The non-standard power into a standard electrical signal, such as 1-5V, 4-20mA, 0-10V, etc..
At the same time, there is also an analog input unit (A/D),
Transform these standard electrical signals into digitaal signals,
The analog output unit (D/A), in order to transform the digital quantity after PLC processing into analog quantity -- standard electric signal A64RD3C Manual A64RD3C User's Manual.
So the standard telecommunication number, the conversiion between the number of operations to use a variety of computing A64RD3C Manual A64RD3C User's Manual.
This requires the resolution of the analog unit and the standard electrical signal.
Related products
MITSUBISHI
Analog output module
A64DAVC
MITSUBISHI Analog output module A64DAVC
4 channels. Input: DC0 20mA. Output r
MITSUBISHI
Temperature input module (RTD)
A64RD3C
MITSUBISHI Temperature input module (RTD) A64RD3C
4 channels. 3 wire type. Platinum resist
MITSUBISHI
Analog output module
A64DAIC
MITSUBISHI Analog output module A64DAIC
4 channels. Input resolution: -4000