MITSUBISHI A2USHCPU-S1 Manual A2USHCPU-S1 User's Manual
Product model: A2USHCPU-S1
Name: PLC
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Output points: 64 points.
Voltage: DC12/24V.
OFF leakage current: 0.1mA.
Output type: transistor output (type sink).
Response time: 2ms.
32 points / a common end.
40 pin connector.
With the surge absorber.
Each scanning process. Focus on the input signal sampling. Focus on the output signal to refresh A2USHCPU-S1 Manual A2USHCPU-S1 User's Manual.
Input refresh process. When the input port is closed,
Program in the implementation phase, the input end of a new state, the new state can not be read A2USHCPU-S1
Only when the program is scanned, the new state is read.
A scan cycle is divided into the input sample, the program execution, the output refresh.
The contents of the component image register are changed with the change of the execution of the program A2USHCPU-S1 Manual A2USHCPU-S1 User's Manual.
The length of the scan cycle is determined by the three.
CPU the speed of executing instructions.
Time of instruction.
Instruction count.
Due to the adoption of centralized sampling.
Centralized output mode.
There exist input / output hysteresis phenomena, i.e., the input / output response delay.
PLC selection with the development of PLC technology, more and more types of PLC products,
Function is becoming more and more perfect, and its application is more and more extensive A2USHCPU-S1 Manual A2USHCPU-S1 User's Manual.
Different series of different models of PLC has different performance, applicable occasions also have different emphasis,
Price also has a greater difference. Therefore PLC selection,
Under the premise of meeting the control requirements,
Should consider the best performance to price ratio, a reasonable choice of PLC.
System program memory for storing system program,
Including management procedures, monitoring procedures, as well as the user program to do the compiler to compile the process of interpretation.
Read only memory. Manufacturers use, content can not be changed, power does not disappear. Input voltage range: AC100-120V/AC200-240V.
Output voltage: DC24V.
Output current: 1.2A additional power supply unit.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined according to the analog quantity aand switch quantity of the controlled object,
Generally an input / output element to take up an input / output point A2USHCPU-S1 Manual A2USHCPU-S1 User's Manual.
Taking into account the future adjustment and expansion,
In general should be estimaated on the total number of points plus the amount of spare 20%~30% A2USHCPU-S1 Manual A2USHCPU-S1 User's Manual.
The following describes the centralized control system I/O points of the estimate.
Related products
MITSUBISHI
Motion controller (upgrade)
Q170MCPU-S1
MITSUBISHI Motion controller (upgrade) Q170MCPU-S1
Axis of control: 16. Compact Q170MCPU in
MITSUBISHI
CPU unit
Q2ASHCPU-S1
MITSUBISHI CPU unit Q2ASHCPU-S1
Input and output points: 1024 points. In
MITSUBISHI
CPU unit
A2SCPU-S1
MITSUBISHI CPU unit A2SCPU-S1
Program memory capacity 14K. Input and o
MITSUBISHI
Moving CPU unit
A73CPU-S1
MITSUBISHI Moving CPU unit A73CPU-S1
Multi axis positioning controller. Progr