LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI A2NCPUR21 Manual A2NCPUR21 User's Manual
Product model: A2NCPUR21
Name: PLC
Brand: MITSUBISHI
Sort: User's Manual
File language: English
DC input points: 32 points.
Input voltage and current: 3/7mA, DC12/24V.
Response time: 10ms.
Positive pole sharing.
Output points: 16 points.
Output voltage and current: 100mA/1, DC12/24V point.
Response time: 2ms.
48 point /1 public side (input and output sharing).
Output form: transistor output, leakage type A2NCPUR21 Manual A2NCPUR21 User's Manual.
40 pin connector.
Number of stations: 1 stops A2NCPUR21
Type remote I/O unit (twisted pair data connection).
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system A2NCPUR21 Manual A2NCPUR21 User's Manual.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong A2NCPUR21 Manual A2NCPUR21 User's Manual.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy to guarantee the timeliness.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer. AnS, QnAS bus connection, the reader to write program 2 channel connection.Input type: DC input, positive public end / negative public end.
Input points: 32 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC5V/4mA.
External connectioon: 1 wire A2NCPUR21 Manual A2NCPUR21 User's Manual.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup.
Finger protection through the upper part of the terminal,,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool A2NCPUR21 Manual A2NCPUR21 User's Manual.
Related products
MITSUBISHI
CPU unit
A2NCPU-S1
MITSUBISHI CPU unit A2NCPU-S1
Input and output points: 1024 points. In
MITSUBISHI
CPU unit
A1NCPUR21
MITSUBISHI CPU unit A1NCPUR21
Input and output points: 256 points. Inp
MITSUBISHI
CPU unit
A2NCPUP21-S1
MITSUBISHI CPU unit A2NCPUP21-S1
Input and output points: 1024 points. In
MITSUBISHI
CPU unit
A3NCPUR21
MITSUBISHI CPU unit A3NCPUR21
Input and output points: 2048 points. In