MITSUBISHI A2NCPU-S1 Common Instructions Manual A2NCPU-S1 Programming Manual
Product model: A2NCPU-S1
Name: Programmable Logic Controller
Brand: MITSUBISHI
Sort: Common Instructions Programming Manual
File language: English
Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 10ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC12V/DC24V/0 A2NCPU-S1 Common Instructions Manual A2NCPU-S1 Programming Manual . 5A.
External connection: 1 line /1 line type A2NCPU-S1
Type of input and output terminal.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module. 2 slots.
Can be installed in the power supply unit for A series units installed QnA/.
When the programmer input programinto the user program memory,
Then CPU according to the function of the system (the system program memory to explain the compiler),
Translate the user program into PLC internally recognized by the user to compile the program A2NCPU-S1 Common Instructions Manual A2NCPU-S1 Programming Manual .
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage A2NCPU-S1 Common Instructions Manual A2NCPU-S1 Programming Manual .
When the internal circuit outputs a digital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is disconnected from the load.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity oof the controlled object,
Generally an input / output element to take up an input / output point A2NCPU-S1 Common Instructions Manual A2NCPU-S1 Programming Manual .
Taking into account the future adjustment and expansion,
In general should be estimaated on the total number of points plus the amount of spare 20%~30% A2NCPU-S1 Common Instructions Manual A2NCPU-S1 Programming Manual .
The following describes the centralized control system I/O points of the estimate.
Related products
MITSUBISHI
CPU unit
A2ASCPU-S1
MITSUBISHI CPU unit A2ASCPU-S1
I/O points: 512. Processing speed: sec/
MITSUBISHI
CPU unit
A1SCPU-S1
MITSUBISHI CPU unit A1SCPU-S1
Program memory capacity: 8k. Input / out
MITSUBISHI
CPU unit
Q2ACPU-S1
MITSUBISHI CPU unit Q2ACPU-S1
Input and output points: 1024 points. In
MITSUBISHI
CPU unit
A2NCPUR21-S1
MITSUBISHI CPU unit A2NCPUR21-S1
Input and output points: 1024 points. In