LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI A273UCPU AD57 control Instructions Manual A273UCPU Programming Manual
Product model: A273UCPU
Name: PLC
Brand: MITSUBISHI
Sort: AD57 control Instructions Programming Manual
File language: English
Analog channel: 16 channels.
Input / output (resolution): 0 ~ 4000.
Conversion speed: 100ms/16 channel.
Analog module installation.
Power supply: DC24V.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system A273UCPU AD57 control Instructions Manual A273UCPU Programming Manual A273UCPU
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is strong A273UCPU AD57 control Instructions Manual A273UCPU Programming Manual.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy to guarantee the timeliness A273UCPU AD57 control Instructions Manual A273UCPU Programming Manual.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer. RS-232 2 channel.
Transfer speed: 0.3-19.2kbps.
Equipment layer / field bus CC-Link device layer is the PLC and other control devices and sensors and drive devices connected to the field network,
Network for the lowest layer of the whole network system.
Using CC-Link field bus connection, the number of wiring is greatly reduced,
Improve the maintainability of the system.
And, not just the amount of data ON/OFF and other switches,
Can also be connected to the ID system, bar code reader, inverter, man-machine interface and other intelligent devvices,
From the completion of a variety of data communication, the management of the terminal production information can be realized,
On the centralized management of the state oof the machine movement,
Make maintenance work efficiency also greatly improved A273UCPU AD57 control Instructions Manual A273UCPU Programming Manual A273UCPU AD57 control Instructions Manual A273UCPU Programming Manual.
Q series PLC in the use of CC-Link function better,
And easier to use.
Related products
MITSUBISHI
General purpose CPU
Q00UCPU
MITSUBISHI General purpose CPU Q00UCPU
nput / output points: 1024 points. Nume
MITSUBISHI
General purpose CPU
Q02UCPU
MITSUBISHI General purpose CPU Q02UCPU
Input / output points: 2048 points. Num
MITSUBISHI
General purpose CPU
Q01UCPU
MITSUBISHI General purpose CPU Q01UCPU
Input / output points: 1024 points. Num