MITSUBISHI A1SD75M2 Manual A1SD75M2 User's Manual
Product model: A1SD75M2
Name: Positioning Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Input points: 16 points.
Input voltage and current: 120V ~ 10mA AC100.
Input response time: 35ms.
16 point /1 a public side.
Output points: 12 points.
Output voltage: DC24V/AC240V, 2A/1 point, 5A/1 common end.
Output response time: 12ms.
Output type: relay output.
8 point /1 a public end, 3 point /1 a public end A1SD75M2 Manual A1SD75M2 User's Manual.
Independent contact.
36 point terminal station A1SD75M2
With the surge absorber.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points A1SD75M2 Manual A1SD75M2 User's Manual.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process A1SD75M2 Manual A1SD75M2 User's Manual.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal andd fan fault signal A1SD75M2 Manual A1SD75M2 User's Manual.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drivee system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points A1SD75M2 Manual A1SD75M2 User's Manual.
Related products
MITSUBISHI
High speed counting module
A1SD62D
MITSUBISHI High speed counting module A1SD62D
Numer of channels: 2 channels. Input si
MITSUBISHI
Positioning control module
A1SD75M2
MITSUBISHI Positioning control module A1SD75M2
Axis of control: 2. Interpolation functi
MITSUBISHI
Positioning control module
A1SD75P2-S3
MITSUBISHI Positioning control module A1SD75P2-S3
Axis of control: 2 axis linkage, 2 axis