LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI A1S64TCTTBW-S1  Hardware Manual A1S64TCTTBW-S1  User's Manual
Product model: A1S64TCTTBW-S1 
Name: Temperature Control Module
Brand: MITSUBISHI
Sort: Hardware User's Manual
File language: English
Input type: DC input, positive public end / negative public end.
Input points: 32 points.
Enter the response time: 0.2ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 1 wire.
According to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup A1S64TCTTBW-S1  Hardware Manual A1S64TCTTBW-S1  User's Manual A1S64TCTTBW-S1 
Finger protection through the upper part of the terminal,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool. Input type: DC input, positive common end.
Input points: 8 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA A1S64TCTTBW-S1  Hardware Manual A1S64TCTTBW-S1  User's Manual.
Output form: transistor output, leakage type.
Output points: 8 points.
OFF leakage current: 0.1mA.
Output protection function: No.
Rated load voltage / current: DC24V/0.5A.
External connection: 3 line /2 line type.
Spring clip terminal.
Do not need to be tightened further or locked with screws, which can reduce the working hours of wiring.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module A1S64TCTTBW-S1  Hardware Manual A1S64TCTTBW-S1  User's Manual.
When installing the module can choose to use the DIN guide rail or screw mounting.
Can be used for the 3 wire sensor input wiring. Input type: DC input, positive common end.
Input points: 32 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 3 wire.
Sensor connector type (E-CON type).
Using industry standard E-CON type.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. Input type: DC input, positive public end / negative public end.
Input points: 8 points.
Enter the response time: 10ms the following.
Rated input voltage / current: DC24V/7mA.
Output form: relay output.
Output points: 8 points. A1S64TCTTBW-S1  Hardware Manual A1S64TCTTBW-S1  User's Manual.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC12V/AC240V/2A.
External connection: 2 line /2 line type.
Type of input and output termminal A1S64TCTTBW-S1  Hardware Manual A1S64TCTTBW-S1  User's Manual.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module.
Related products
MITSUBISHI
Temperature control module
A1S64TCTTBW-S1
MITSUBISHI Temperature control module A1S64TCTTBW-S1
Numer of channels: 4 channels. Sensing