LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI A1S62TCTTBW-S2 Hardware Manual A1S62TCTTBW-S2 User's Manual
Product model: A1S62TCTTBW-S2
Name: Heating-Cooling Temperature Control Module with Wire Breakage Detection Function
Brand: MITSUBISHI
Sort: Hardware User's Manual
File language: English
Common cathode input module (standard type).Ethernet network module 10BASE-T/10BASE5.
Control layer /MELSECNET/10 (H) is the middle layer of the whole network system,
Control network which is convenient and high speed processing data transmission between PLC, CNC and other control equipment.
As MELSEC control network MELSECNET/10,
With its good real-time performance, simple network settings, no procedures of the network data sharing concept,
As well as the redundant circuit and so on, has obtained the very high market appraisal,
The number of devices to reach the highest in japan,
In the world is also one of the few A1S62TCTTBW-S2 Hardware Manual A1S62TCTTBW-S2 User's Manual A1S62TCTTBW-S2
And MELSECNET/H not only inherited the excellent characteristics of MELSECNET/10,
Also makes the network real-time better, more data capacity,
Further adapt to the needs of the market A1S62TCTTBW-S2 Hardware Manual A1S62TCTTBW-S2 User's Manual. Input channel number: 2.
Output channel number: 1.
Occupy I/O points: 32.
A1S63ADA analog input / output combination components can be analog / digital / digital / analog conversion,
The input and output signals can be voltage or current,
Offset and gain can be set and stored.
The length of time required to execute the instruction, the length of the user''s program, the type of instruction, and the speed of the CPU execution are very significant,
Generally, a scanning process, the fault diagnosis time,
Communication time, input sampling and output refresh time is less,
The execution time is accounted for the vast majority of A1S62TCTTBW-S2 Hardware Manual A1S62TCTTBW-S2 User's Manual.
The response time of PLC is the interval between the time of the change of the external output signal of the PLC and the time of the change of the external output signal which is controlled by it,
Lag time, this is the time constant of the input circuit,
The time constant of the output circuit, the arrangement of the user statement and the use of the instruction,
The cycle scan mode of PLC and the way of PLC to refresh the I/O and so on.
This phenomenon is called the I/O delay time effect. Output type: relay output.
Output points: 8 points.
OFF leakage current: -.
Output protection function: No.
Rated load voltage / current: DC24V/AC240V/2A.
External connection: 2 wire.
Accordiing to the external connection mode and the external equipment input and output specifications,
Choose from a rich product lineup A1S62TCTTBW-S2 Hardware Manual A1S62TCTTBW-S2 User's Manual.
Finger protection through the upper part of the terminal,,
The human body will not be exposed to live parts,
Therefore, the terminal station type remote I/O module can be directly mounted to the machine tool A1S62TCTTBW-S2 Hardware Manual A1S62TCTTBW-S2 User's Manual.
Related products
MITSUBISHI
Temperature control module
A1S62TCTT-S2
MITSUBISHI Temperature control module A1S62TCTT-S2
Numer of channels: 2 channels. Sensing
MITSUBISHI
Temperature control module
A1S62TCRTBW-S2
MITSUBISHI Temperature control module A1S62TCRTBW-S2
Numer of channels: 2 channels. Sensing
MITSUBISHI
Temperature control module
A1S62TCRT-S2
MITSUBISHI Temperature control module A1S62TCRT-S2
Numer of channels: 2 channels. Sensing
MITSUBISHI
Temperature control module
A1S62TCTTBW-S2
MITSUBISHI Temperature control module A1S62TCTTBW-S2
Numer of channels: 2 channels. Sensing