MITSUBISHI A1S62TCRT-S2 Manual A1S62TCRT-S2 User's Manual
Product model: A1S62TCRT-S2
Name: Heating-Cooling Temperature Control Module
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Cable length: 15 meters.
For QCPU and GOT (need A9GT-QCNB) connection.
For the connection between GOT and GOT. 16 channels.
Input: DC-10 ~ 10V, DC-20 ~ 20mA.
38 point terminal station.
Analog quantity I/P multiplexing unit (isolation channel).
Detailed analysis of the process and work characteristics of the controlled object,
To understand the coordination between the controlled object machine, electricity and liquid,
The control requirements of the controlled object for MITSUBISHI PLC control system are put forward,
Determine the control program, to develop a design task book A1S62TCRT-S2 Manual A1S62TCRT-S2 User's Manual A1S62TCRT-S2
How to determine the input / output device of MITSUBISHI plc.
According to the control requirements of the system,
All input devices and output devices required for the determination of the system,
To determine the input / output device related to the MITSUBISHI PLC,
To determine the I/O PLC points A1S62TCRT-S2 Manual A1S62TCRT-S2 User's Manual. Cable length: 1 meters.
The connection between the A0J2HCPU power supply unit (A0J2-PW) and the GOT. Output type: transistor drain.
Output points: 16 points.
Load voltage: DC24.
Load current: 2A.
Connection mode: terminal row A1S62TCRT-S2 Manual A1S62TCRT-S2 User's Manual.
Common public end points: 8.
Switching value, also known as logic, refers to only two values, 0 or 1, ON or OFF.
It is the most common control, it is the advantage of PLC control,
Is also the most basic application of PLC.
Switch volume control is designed to,
According to the current input combination of the switch quantity and the history of the input sequence,
So that PLC generates the corresponding switching output,
In order to make the system work in a certain order.
So, sometimes also known as the order control.
And sequential control is divided into manual, semi-automatic or automatic.
And the control principle is decentralized, centralized and hybrid control three. Input type: DC input, negative public end.
Input pooints: 32 points A1S62TCRT-S2 Manual A1S62TCRT-S2 User's Manual.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 3 wire.
Sensor connector type (E-CON type).
Using industry standard E-CONN type A1S62TCRT-S2 Manual A1S62TCRT-S2 User's Manual.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input.
Related products
MITSUBISHI
Temperature control module
A1S62TCTT-S2
MITSUBISHI Temperature control module A1S62TCTT-S2
Numer of channels: 2 channels. Sensing
MITSUBISHI
Temperature control module
A1S62TCRT-S2
MITSUBISHI Temperature control module A1S62TCRT-S2
Numer of channels: 2 channels. Sensing
MITSUBISHI
Temperature control module
A1S62TCRTBW-S2
MITSUBISHI Temperature control module A1S62TCRTBW-S2
Numer of channels: 2 channels. Sensing
MITSUBISHI
Temperature control module
A1S62TCTTBW-S2
MITSUBISHI Temperature control module A1S62TCTTBW-S2
Numer of channels: 2 channels. Sensing