MITSUBISHI A171SCPU Manual A171SCPU User's Manual
Product model: A171SCPU
Name: MOTION CONTROLLER
Brand: MITSUBISHI
Sort: User's Manual
File language: English
Cable connection and A7PU/A7HGP/A6GPP CPU,
Cable length 3 meters.
Provide A7HGP-SET/A6GPP-SET. A set of 5 (LOGO removable, man-machine interface provides one).
Applicable model: A960GOT. Storage capacity: 16MB.
Applicable models: A985 (-V) /A975/A970/A960GOT (-B). Input points: 32 points.
Input voltage and current: 120V ~ 10mA AC100 A171SCPU Manual A171SCPU User's Manual.
Input response time: 35ms A171SCPU
16 point /1 a public side.
Output points: 24 points.
Output voltage: DC24V/AC240V, 2A/1 point, 5A/1 common end.
Output response time: 12ms.
Output type: relay output.
8 point /1 a public side.
36 point terminal station.
Control solenoid valve required I/O points by the action principle of the solenoid valve can be known,
A single coil solenoid valve with PLC control to 2 input and 1 output,
A double coil solenoid valve requires 3 inputs and 2 outputs,
A button needs an input; a light sensitive switch needs 4 or 2 inputs,
A signal lamp needs 1 output, band switch,
Several bands are required for several inputs,
In general, a variety of position switches are required to take up 2 input points A171SCPU Manual A171SCPU User's Manual.
MITSUBISHI PLC is the main product in the production of MITSUBISHI motor in Dalian A171SCPU Manual A171SCPU User's Manual.
It uses a kind of programmable memory for its internal storage procedures,
Execute logic operation, sequence control, timing, counting and arithmetic operations, user oriented instruction,
And through digital or analog input / output control of various types of machinery or production process.
The number of I/O thyristor DC motor control required tube DC motor speed control system is the main form of DC speed regulation,
The thyristor rectifier unit is used to supply power to the DC motor.
PLC control of the DC drive system, the input of the PLC in addition to the main signal outside the signal,
We need to consider the switching signal, the fault signal transmission device, brake signal and fan fault signal A171SCPU Manual A171SCPU User's Manual.
The output of the PLC mainly consider the speed command signal positive 1~3 level, 1~3 level, allowing reverse switching signal and brake open signal etc..
In general, a reversible DC drivee system controlled by PLC is approximately 12 input points and 8 output points,
An irreversible DC drive system requires 9 inputs and 6 output points A171SCPU Manual A171SCPU User's Manual.
Related products
MITSUBISHI
CPU unit
A171SHCPUN
MITSUBISHI CPU unit A171SHCPUN
CPU:A2SHCPU PLC is the same. PLC program
MITSUBISHI
CPU unit
A2ASCPU
MITSUBISHI CPU unit A2ASCPU
I/O points: 512. Processing speed: sec/
MITSUBISHI
Motion controller
Q173DSCPU
MITSUBISHI Motion controller Q173DSCPU
Control axis: up to 32 axes. Servo ampli
MITSUBISHI
CPU unit
A2SCPU
MITSUBISHI CPU unit A2SCPU
Program memory capacity 14K. Input and o