LK Automation Limited LK Automation Limited
Download Sort: MITSUBISHI
Home >> Manual Download
MITSUBISHI A0J2CPUP23 Dedicated Instructions Manual A0J2CPUP23 Programming Manual
Product model: A0J2CPUP23
Name: PLC
Brand: MITSUBISHI
Sort: Dedicated Instructions Programming Manual
File language: English
MELSECNET/10, MELSECNET/H coaxial.
Input voltage: DC24V.
How to choose MITSUBISHI PLC.
MITSUBISHI PLC options include the choice of MITSUBISHI PLC models, capacity, I/O module, power, etc..
MITSUBISHI PLC distribution I/O points and design MITSUBISHI PLC peripheral hardware circuit
Draw the I/O point of the PLC and the input / output device connection diagram or the corresponding table,
This part also can be carried out in second steps A0J2CPUP23 Dedicated Instructions Manual A0J2CPUP23 Programming Manual A0J2CPUP23
Design PLC peripheral hardware circuit.
Draw the electrical wiring diagram of the other parts of the system,
Including the main circuit and the control circuit does not enter the PLC, etc..
The electrical schematic diagram of the system composed of I/O PLC connection diagram and PLC peripheral electrical circuit diagram A0J2CPUP23 Dedicated Instructions Manual A0J2CPUP23 Programming Manual.
So far the system''s hardware electrical circuit has been determined. Input voltage range: DC24V.
Output voltage: DC5V.
Output current: 2.5A.
I/O points is an important indicator of PLC.
Reasonable selection of I/O points can not only satisfy the control requirements of the system,
And the total investment of the system is the lowest A0J2CPUP23 Dedicated Instructions Manual A0J2CPUP23 Programming Manual.
The input and output points and types of PLC should be determined according to the analog quantity and switch quantity of the controlled object,
Generally an input / output element to take up an input / output point.
Taking into account the future adjustment and expansion,
In general should be estimated on the total number of points plus the amount of spare 20%~30%.
The following describes the centralized control system I/O points of the estimate.
Relay output interface circuit of PLC
Working process: when the internal circuit output digital signal 1,
There is a current flowing through, the relay coil has a current, and then the normally open contact is closed,
Provide load current and voltage.
When the internal circuit outputs a ddigital signal 0, there is no current flowing through it,
The relay coil does not have a current, and the normally open contact is broken off,
A current or voltage that is discoonnected from the load A0J2CPUP23 Dedicated Instructions Manual A0J2CPUP23 Programming Manual A0J2CPUP23 Dedicated Instructions Manual A0J2CPUP23 Programming Manual.
It is through the output interface circuit to the internal digital circuit into a signal to make the load action or not action.
Related products
MITSUBISHI
CPU unit
A0J2CPU-DC24-S2
MITSUBISHI CPU unit A0J2CPU-DC24-S2
Input and output points: 480 points. Pro
MITSUBISHI
CPU unit
A0J2CPU-DC24
MITSUBISHI CPU unit A0J2CPU-DC24
Input and output points: 480 points. Pro
MITSUBISHI
CPU unit
A0J2CPUP23
MITSUBISHI CPU unit A0J2CPUP23
Input and output points: 480 points. Pro
MITSUBISHI
CPU unit
A0J2CPUR23
MITSUBISHI CPU unit A0J2CPUR23
Input and output points: 480 points. Pro