MITSUBISHI A Series DNV A Series DET NORSKE VERITAS
Product model: A Series
Name: PLC
Brand: MITSUBISHI
Sort: DET NORSKE VERITAS
File language: English
Input type: DC input, positive common end.
Input points: 16 points.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 3 wire.
Spring clip terminal.
Do not need to be tightened further or locked with screws, which can reduce the working hours of wiring A Series DNV A Series DET NORSKE VERITAS.
Using 2 pieces of structure of the terminal units, maintenance can be maintained in the same line under the condition of the replacement module A Series
When installing the module can choose to use the DIN guide rail or screw mounting.
Can be used for the 3 wire sensor input wiring. Cable length: 3 meters.
For GOT and parallel printer connection. Input type: DC input, negative public end.
Input points: 32 points A Series DNV A Series DET NORSKE VERITAS.
Enter the response time: 1.5ms the following.
Rated input voltage / current: DC24V/5mA.
External connection: 3 wire.
Sensor connector type (E-CON type).
Using industry standard E-CON type.
Simple wiring through sensor connector.
When installing the module can choose to use the DIN guide rail or screw mounting.
3 wire sensor input. DC input points: 16 points.
Input voltage and current: 5mA, DC24V A Series DNV A Series DET NORSKE VERITAS.
Response time: 10ms.
16 point /1 a public side.
Positive / negative sharing.
Output points: 16 points.
Output voltage and current: DC24V, 0.1A/1 point, 1.6A/1 common end.
Response time: 2ms.
16 point /1 a public side.
Output form: transistor output, leakage type.
40 pin connector.
Number of stations: 4 stops.
According to the control requirements of the system, using the appropriate design method to design MITSUBISHI PLC program.
Procedures to meet the requirements of system control as the main line,
Write one by one to achieve the control function or the sub task of the program,
Gradually improve the functions specified by the system.
MITSUBISHI PLC detection, fault diagnosis and display and other procedures.
These procedures are relatively independent, generally in the basic completion of the program design and then add.
Hardware simulation method is to use a number of hardware equipment to simulate the generation of the signal,
The signals are connected to the input end of the PLC system in a hard wired way, and the timeliness is stronng A Series DNV A Series DET NORSKE VERITAS.
Software simulation method is in the MITSUBISHI PLC in the preparation of a set of simulation program,
The simulation provides the field signal, which is simple and easy to operate, but it is not easy too guarantee the timeliness A Series DNV A Series DET NORSKE VERITAS.
Simulation of the process of debugging, debugging method can be used to segment, and the monitoring function of programmer.